S-ANALYZER 200 BMBT series is Paramagnetic oxygen gas measurement device, a multi-gas analyzer for 19"rack-mounting, configured with two gas streams, two gas inlets and two gas outlets. S-ANALYZER 200 BMBT is equipped with a touchscreen. In combination with a well-arranged menu structure, intuitive and user-friendly operations is assured. All necessary status-, threshold-, and alarm messages for effective monitoring are provided as analogue and digital signals. Graphic display of measurement curves are also as option offered.
Type :
S-ANALYZER 200 BMBTS-ANALYZER 200 BMBT series is equipped with high-precision paramagnetic oxygen sensors, with a detection resolution of 0.001%, which meets strict industry standards. Simultaneously equipped with various infrared gas sensors, detecting the concentration of gases such as carbon monoxide, carbon dioxide, methane, etc., and accurately completing gas quantitative analysis.
S-ANALYZER 200 BMBT series is a multi-gas analyzer for 19"rack-mounting, configured with two gas streams, two gas inlets and two gas outlets. S-ANALYZER 200 BMBT is equipped with a touchscreen. In combination with a well-arranged menu structure, intuitive and user-friendly operations is assured. All necessary status-, threshold-, and alarm messages for effective monitoring are provided as analogue and digital signals. Graphic display of measurement curves are also as option offered.
Product Advantages:
Specification:
Product Type |
S-ANALYZER 200 BMBT |
Response time |
General:<25s (t90 @60 L/h Constant Flow) |
Warm up Time |
3min~30minn @amibent 20℃ (accord different detector configuration) |
Digital Res. (@zero |
General: - 0.01Vol.% in case of percent range (e.g. 0.001Vol.% for BMBT O2 channel) - 0.1 µmol/mol in case of µmol/mol range |
Operation Handling |
Touch panel, 5.6” TFT |
Analog Output |
4mA~20mA (normal operation) 2mA (in warm-up or status alarm) |
Analog Output Range |
Default is 4mA for lower range, and 20mA for upper range. User setable. |
Relay contact output |
Relay out quantity: x6 With relay out assignment for: x1 instrument error alarm x1 sample gas control valve relay signal for auto. cali. x1 auto. cali. zero gas supply control valve relay signal xN (N is channel quantity) auto. cali. span gas supply control valve relay signal xN (N is channel quantity) gas concentration upper/lower alarm |
Relay Property |
1A contact (250V AC/2A, resistive load) |
Communication |
Standard RS232 (DB-9 female) RS485 with modbus protocol. |
Operating Voltage |
98~242V AC, 50/60 Hz. Power consumption <125W |
Power inlet |
EN60320 C1 |
Fuse |
Fuse Current: 3A ,Blow Characteristic: Fast Acting Fuse Size Metric: 5mm x 20mm |
Case Protection Level |
IP41 (EN60529) |
Weight |
typical approx. 10kg (w/o package) approx. 19kg (w/ package) |
Gas Inlet Flow |
0.4~0.8 L/min (Flow fluctuations ≤0.02 L/min) |
Inlet Gas Temp. |
5~35 ℃ |
Inlet Gas Pressure |
116kPa (max) |
Moisture in Gas |
• not condensing • inlet gas dew point:5℃±0.1℃ (This item is required when measure channel include NDIR SO2 and/or NO) |
Dust in gas flow |
100µg/m³, ≤1µm |
Zero calibration gas |
99.999Vol.% N2 (typical) |
3th point(middle point) calibration gas range |
Allow range: 0.375*FS~0.625*FS
|
Span calibration gas range (user calibration) |
Allow range: 0.75*FS~1.25*FS
|