Search
S-ANALYZER 200 ATEX is an industrial explosion-proof multi-component Industry ATEX Gas analyzer that can simultaneously detect up to five components of gases. Explosion-proof class ExdIICT6 Gb. The analyzer is equipped with display screen and explosion-proof button to display the detection concentration in real time, which is suitable for the detection of gas concentration in various industrial occasions.
Type :
SA-200 ATEXIndustry ATEX Gas analyzer Application:
Product Advantages:
Specification:
Product Type |
S-ANALYZER 200 ATEX V5.0 |
Channel |
Max. 5 different gases in mixture •Configuration refer analyzer type plate or inspection report. •Gas configuration information includes - Measuring gas type - Measurement range - Measuring Error |
Response time |
General:<25s (t90 @60 L/h Constant Flow) |
Warm up Time |
3min~30min (accord different detector configuration) |
Digital Resolution (@zero) |
General: - -0.01Vol% in case of 0-10Vol.% range - -0.1Vol% in case of 0-100Vol.% range - 0.1 µmol/mol[ 1 µmol/mol = 1 ppm] in case of µmol/mol range |
Operation Handling |
explosion proof buttons |
Analog Output |
4mA~20mA (normal operation) 2mA (in warm-up or status alarm) Analog output channel quantity same as gas measure channel quantity |
Permissible load resistance |
250Ω~350Ω |
Relay contact output |
Relay out quantity: x6 With relay out assignment for: •x1 instrument error alarm •x1 sample gas control valve relay signal for auto. cali. •x1 auto. cali. zero gas supply control valve relay signal •xN (N is channel quantity) auto. cali. span gas supply control valve relay signal •xN (N is channel quantity) gas concentration upper/lower alarm |
Relay Property |
1A contact (250V AC/2A, resistive load) |
Gas Connection |
NPT 1/8” female |
Operating Voltage |
(198~242)V AC, 50/60 Hz, power consumption <125W |
Cable gland |
Explosion proof cable gland TDJT-15 ∅6~∅13mm |
Fuse |
Fuse Current: 3A ,Blow Characteristic: Fast Acting Fuse Size Metric: 5mm x 20mm |
Ex Level |
ExdIICT6 Gb (containing C2H2) Certificate No.: GYB17.1096X The product has been inspected by the National Instrument and Explosion Safety Supervision and Inspection Station (NEPSI) and meet the following standards: GB3836.1-2010 Explosive atmosphere Part 1: Equipment General requirements GB3836.2-2010 Explosive atmosphere Part 2: Equipment protected by flameproof enclosure "d" |
Weight |
~50Kg (typical) |
Gas Inlet Flow |
(0.4~0.8)L/min (Flow fluctuations ≤0.02 L/min) |
Inlet Gas Temp. |
(5~35)℃ |
Inlet Gas Pressure |
(76~116)kPa |
Moisture in Gas |
• not condensing • inlet gas dew point:5℃±0.1℃ (This item is required when measure channel include SO2 and/or NO) |
Dust in gas flow |
100µg/m³, ≤1µm |
Zero calibration gas |
99.999% N2 |
3th point(middle point) calibration gas range |
Allow range: 0.375*FS~0.625*FS |
Span calibration gas (user calibration) |
Allow range:0.75*FS~1.25*FS |
Operating Temp. |
5℃~45℃ |
Ambient Humidity |
0% RH~95% RH (not condensing) |
Ambient Air Pressure |
76kPa~116kPa |