Mobile oxygen supply system for ambulances

Mobile oxygen supply system for ambulances
Mobile oxygen supply system for ambulances

Mobile oxygen supply system for ambulances

Ambulance is an indispensable part of the modern emergency medical service system, is the activity place for medical personnel to rescue critically ill patients before hospital and on the spot, is an important part of modern emergency medicine, especially in response to public health emergencies, saving patients' lives play a key role.

negative pressure ambulance, can achieve in-car first aid.

  • Type :

    Oxygen supply system

Ambulances can be divided into three types from the use of function, which are: transport type (transfer type), monitoring type and negative pressure type. The transfer ambulance is the simplest of the three types of ambulances, mainly responsible for the transfer of patients. It can be converted into a monitoring ambulance or a negative pressure ambulance by adding medical equipment and installing a negative pressure system.

 

HEYER has a series of ambulance products, can be installed in the ambulance, converted into a monitoring or negative pressure ambulance, can achieve in-car first aid.

 

Product Advantages:

  • Develop and manufacture high quality medical gas supply equipment and accessories
  • Easy to use, can rescue patients in the car, to achieve the first time emergency rescue.
  • equipped with sound and light alarm system
  • The dedicated oxygen decompression panel in the ambulance makes it easy to supply oxygen inside the vehicle

 

Specification:

Pressure relief panel composition

Pressure sensor

Oxygen pressure reducing valve 200bar-5bar

Solenoid valve 24v, bypass, manual switching device

Cylinders are automatically switched one by one

Sound and light alarm system

It can display the digital status of the pressure reduction panel and issue sound and light alarm when the pressure is abnormal

Oxygen humidification unit for ambulances

Concealed humidifier

1-4 channels Single or four channels at the same time

Flow gear adjustment 1-9 0-15L/min (customizable)

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products

Medical Gas Outlets
Medical Gas Outlets

The HEYER Medical Gas Outlets are used in gas supply plants for medical premises in accordance with DIN EN ISO 7396-1. The connector is supplied in different versions and installation variants. The installation in solid walls, lightweight walls, ceiling supply units, this allows bed rails, intensive care units, etc. In principle, HEYER medical gas connectors can be plugged into all Deck supply units, energy supply units and gas boxes of all kinds Manufacturers and variants are installed.

Medical anesthesia exhaust outlets
Medical anesthesia exhaust outlets

The HEYER AGSS anesthesia gas recovery and discharge system can prevent users or staff from inhaling the anesthetic exhaust gas left by the operating room gas circulation system, ensuring the safe use of anesthesia gas in hospitals. Jet anesthesia exhaust gas discharge system is an independent discharge system, will not be interfered by other operating rooms or systems, compared with the first generation of negative pressure discharge system, technically safer and more stable; Lower cost in terms of construction; Can be used intermittently, more convenient.

Medical gas source switching device
Medical gas source switching device AGS

The HEYER switching device (model: AGS 35-50 \ AGS 80) is a system that can automatically switch between two sets of gas cylinders through an adjustable switching valve. This process is carried out under the control of a switching valve, which automatically and accurately switches based on the difference in the preset pressure range.

Medical pressure Control panels
Medical pressure Control panels

The HEYER two-stage pressure regulator system is used for the central station air compressor unit, liquid oxygen storage tank and each ward in the complex building. The secondary pressure regulator system can adjust the pressure in the pipeline to meet the different needs of the hospital.

Medical Control & valve alarm device
Medical Control & valve alarm device

For operational safety and better monitoring, the pipeline of the central oxygen supply system is usually divided into multiple areas.   When dealing with faults and detections in the central oxygen supply system, we suggest that each ward be managed independently. The area cut-off alarm box is equipped with an emergency shut-off device for the air circuit, while also ensuring the reliable operation of other normal systems.

Adsorption dryer ATM
Adsorption dryer ATM

The Adsorption dryer ATM dries and purifies the compressed air supplied by the compressor and provides medical breathing air. The air is thereby dried alternately in one of the drying agent vessels. The dried air is subsequently purified in the third vessel, whereby oil residue and other contaminants are removed.

Mobile oxygen supply system for ambulances
Mobile oxygen supply system for ambulances

Ambulance is an indispensable part of the modern emergency medical service system, is the activity place for medical personnel to rescue critically ill patients before hospital and on the spot, is an important part of modern emergency medicine, especially in response to public health emergencies, saving patients' lives play a key role. negative pressure ambulance, can achieve in-car first aid.

leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
submit

home

products

WhatsApp

Contact