The HEYER switching device (model: AGS 35-50 \ AGS 80) is a system that can automatically switch between two sets of gas cylinders through an adjustable switching valve. This process is carried out under the control of a switching valve, which automatically and accurately switches based on the difference in the preset pressure range.

  • Type :

    AGS 35-50 \ AGS 80

The HEYER switching device comes in multiple models and is suitable for different application scenarios, such as small hospital oxygen station gas supply sources, large hospital oxygen station backup gas supply sources, special gas supply sources for operating rooms, and special gas supply sources for reproductive centers.

 

Product Advantages:

  • Fully automatic switching between main and backup air sources is achieved through a high-performance switching valve
  • The maximum flow rate can reach 160m3/h, and the system status is displayed in real-time through an LCD display screen
  • The internal first and second level pressure reduction adopts a one in use and one backup design, which can be maintained with gas
  • Configure the third emergency access port to NIST gas source, which can still automatically switch after a power outage to ensure continuous gas supply
  • Real time monitoring of the pressure of the manifold exhaust cylinder and the output pressure of the pipeline, and implementing sound and light alarms for high and low pressure states. The alarm status is transmitted to the central monitoring system platform through remote communication modules
  • Display online the inventory of left and right gas cylinder groups, the pressure of the third gas source, the working pressure of the system, and the outlet pressure of the pipeline
  • The working pressure of the system is the pressure after first level pressure reduction, and the outlet pressure of the pipeline is the output pressure that enters the pipeline network after second level pressure stabilization
  • Implement high and low pressure audible and visual alarms for various pressure states, and remotely transmit the alarm signals to the central monitoring system platform
  • Alarm signals are transmitted in real-time to the central monitoring system platform through remote communication modules
  • Real time display of the switching valve position and the air source being used
  • Real time detection of gas flow rate, and reading of gas flow rate through the right mute button
  • The system automatically records the date and time of gas cylinder replacement
  • Real time recording of system faults and tracing through calling device fault logs
  • The gas consumption of gas cylinders, pressure status after pressure reduction, output pressure status, gas flow rate, gas source activation status, ambient temperature, and internal lighting of the equipment can be set as needed through the system menu

 

Specification:

AGS 35-50 Switching device (standard)

O2/N2O/CO2/N2/Air  

Pneumatic switching principle (differential pressure type), the maximum flow of 50m3/h

AGS 80 D Switching device (high configuration)

O2/N2O/CO2/N2/Air  

Electromagnetic switching principle, flow 80-160m3/h

AGS 80 P Switching device (standard)

O2/N2O/CO2/N2/Air   

Pneumatic switching principle (differential pressure type), flow 80-160m3/h

AGS 35-50 Switching device (standard)

O2/N2O/CO2/N2/Air  

Pneumatic switching principle (differential pressure type), the maximum flow of 50m3/h

For other parameters or type requirements, contact the manufacturer

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products

Medical Gas Outlets
Medical Gas Outlets

The HEYER Medical Gas Outlets are used in gas supply plants for medical premises in accordance with DIN EN ISO 7396-1. The connector is supplied in different versions and installation variants. The installation in solid walls, lightweight walls, ceiling supply units, this allows bed rails, intensive care units, etc. In principle, HEYER medical gas connectors can be plugged into all Deck supply units, energy supply units and gas boxes of all kinds Manufacturers and variants are installed.

Medical anesthesia exhaust outlets
Medical anesthesia exhaust outlets

The HEYER AGSS anesthesia gas recovery and discharge system can prevent users or staff from inhaling the anesthetic exhaust gas left by the operating room gas circulation system, ensuring the safe use of anesthesia gas in hospitals. Jet anesthesia exhaust gas discharge system is an independent discharge system, will not be interfered by other operating rooms or systems, compared with the first generation of negative pressure discharge system, technically safer and more stable; Lower cost in terms of construction; Can be used intermittently, more convenient.

Medical gas source switching device
Medical gas source switching device AGS

The HEYER switching device (model: AGS 35-50 \ AGS 80) is a system that can automatically switch between two sets of gas cylinders through an adjustable switching valve. This process is carried out under the control of a switching valve, which automatically and accurately switches based on the difference in the preset pressure range.

Medical pressure Control panels
Medical pressure Control panels

The HEYER two-stage pressure regulator system is used for the central station air compressor unit, liquid oxygen storage tank and each ward in the complex building. The secondary pressure regulator system can adjust the pressure in the pipeline to meet the different needs of the hospital.

Medical Control & valve alarm device
Medical Control & valve alarm device

For operational safety and better monitoring, the pipeline of the central oxygen supply system is usually divided into multiple areas.   When dealing with faults and detections in the central oxygen supply system, we suggest that each ward be managed independently. The area cut-off alarm box is equipped with an emergency shut-off device for the air circuit, while also ensuring the reliable operation of other normal systems.

Adsorption dryer ATM
Adsorption dryer ATM

The Adsorption dryer ATM dries and purifies the compressed air supplied by the compressor and provides medical breathing air. The air is thereby dried alternately in one of the drying agent vessels. The dried air is subsequently purified in the third vessel, whereby oil residue and other contaminants are removed.

Mobile oxygen supply system for ambulances
Mobile oxygen supply system for ambulances

Ambulance is an indispensable part of the modern emergency medical service system, is the activity place for medical personnel to rescue critically ill patients before hospital and on the spot, is an important part of modern emergency medicine, especially in response to public health emergencies, saving patients' lives play a key role. negative pressure ambulance, can achieve in-car first aid.

leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
submit

home

products

WhatsApp

Contact