Search
To achieve the goal of green ships, the International Maritime Organization (IMO) proposes to reduce carbon emissions and improve ship energy efficiency, with reducing ship carbon emissions as a key management measure.
In order to reduce carbon emissions and eliminate greenhouse gas emissions from international shipping as soon as possible, the IMO has formulated three stages of measures: first, short-term measures to improve the technology and operational efficiency of new and existing ships, and initiate actions to research and develop new technologies such as alternative fuels; The second is mid-term measures, such as introducing alternative low-carbon and zero carbon fuel implementation plans, strengthening technological cooperation and capacity building, etc; The third is long-term measures, introducing zero carbon fuels and encouraging the widespread adoption of possible new emission reduction mechanisms.
During this process, real-time monitoring of ship gas emissions has become a particularly important aspect. Continuous emission detection system can be used.
The continuous emission monitoring system is a complete monitoring equipment composed of analytical instruments and supporting devices used to continuously monitor the concentration and emission amount of particulate and gas pollutants from fixed pollution sources. It is also known as the "continuous emission monitoring system" CEMS. CEMS system can monitor parameters such as SO2, NO2, CO, dust, temperature, pressure, flow rate, humidity, etc. in gases, and can also expand the monitoring of parameters such as VOCs, NH3, CO, CO2, H2S, etc. for specific occasions.
Type :
CGC-400SIGAS CGC-400 Marpol Emmission gas monitoring system monitor CO2、SO2、NO、NO2、O2 of ship exhaust gas and the component of characteristic factor pollutants in fixed emitters. CGC-400 use NDIR and NDUV detection technology to detect different pollutant for various factor. CGC-400 can also fulfill different customer OEM requirement to add other components or function.
Measurement Components:
Product Advantages:
Specification:
System data |
|
Power supply |
AC 220V±10%,50Hz±1Hz,8KW(Including system equipment and air condition) |
Equipment Air |
(0.4-0.6)MPa, Gas consumption 15Nm3/h, Dew pooint:-20℃, oil free, water free |
Output signal |
DCA(4-20)mA; Operation(Auto,Manual), Maintaining, Malfunction; RS485, RS232, TCP/IP |
Environment Temp. |
5℃~55℃ |
Environment Humidity |
≤90% rel. |
Pressure |
86-106kPa |
Measurement Items |
• CO2 • SO2 • NO • NO2 •O2 |
Sampling |
Sampling Probe + high Temp. Sampling process+Rapid condensation method |
Monitoring points |
2 (can be expanded) |
Monitoring system |
Online gas analyzer |
Equipment Cabinet |
Cabinet accessories: online gas analyzer, cooler, system control unit, system analysis gas path unit; Control power supply: 220 VAC; Protection grade: IP55 |
Sampling Probe |
Protection level: IP65 Heating power: 400W |
Gas Measurement |
|
Online gas analyzer |
Measurement component and range: CO2 : (0~10) % (can be expanded) SO2 : (0~200) ppm (can be expanded) NO : (0~300) ppm (can be expanded) NO2 : (0~200) ppm (can be expanded) O2 : (0~25) % Measuring method: NDIR, NDUV, EC Linear error: ≤± 1% FS Repeatability: ≤± 1% FS Response time (T90): < 30 seconds Resolution: 0.1ppm, 0.01% Inlet gas flow: 0.4l/min-0.8l/min Display: LCD screen Operating language: Chinese and English, switchable Warm up time: ≤ 30min Output: 4-20mA, alarm signal, RS232, RS485,TCP/IP Installation in analysis cabinet |